Worcester EE: electronics or PCB fault on a Greenstar
EE differs from most Worcester codes in that it does not point at a specific mechanical part like a pump or sensor — it flags a fault within the control electronics themselves. That makes accurate diagnosis more important, not less, because PCBs are one of the costlier components on the appliance.

What matters most with a Worcester EE electronics fault
- Supply voltage and earthing are checked before the PCB is blamed
- Poor mains supply can mimic an internal electronics fault
- Manufacturer reset procedures are tried before parts are ordered
- PCBs are a higher-cost component, so diagnosis matters more here
- A persistent fault after checks confirms rather than assumes the board
A Worcester EE electronics fault: the short technical version
Before a control board is condemned, an engineer checks the supply voltage and earthing at the appliance, since electrical supply issues can present as internal PCB faults without the board itself being at fault. Software or configuration resets are attempted where the manufacturer's procedure allows it, and only where the fault persists after those checks is the board itself treated as the cause.
Scope of work
- Domestic boiler installation
- Boiler servicing
- Boiler maintenance and repair
Where we deal with this
Questions we get asked
- Is a PCB always the cause of an EE code?
- No — supply and earthing issues can produce the same symptom without the board itself needing replacement.
- How long does a PCB replacement take?
- It depends on parts availability for your specific model; your engineer can confirm lead time once diagnosis is complete.
Get a Worcester EE electronics fault looked at properly
Where this leaves you: EE deserves a careful electrical check before parts are ordered — it is often cheaper than the code first suggests.
Use the enquiry form to describe the appliance, fault code and what changed before the problem started.
Related help pages
- Electrical faultRCD tripping every time the boiler tries to start
- Pressure lossBoiler losing pressure: how to find the leak that is not obvious
- Flow faultWorcester A1 fault: pump running dry or no flow detected
- Hot water faultCombi hot water scalding hot then cold: flow and control faults
- Landlord complianceCP12 versus an annual service: how landlords should read them
- Property typeFlats with a shared communal flue: what owners need to know
Services that cover this
New Worcester boiler with a 10 year guarantee*
Free no-obligation quotes for installation, servicing & repairs across BA & BS postcodes.